1. Save the current configuration by doing a Backup and Download of all config and voice data
(System->Configuration Management->Backup and download all config and voice
data).
2. Perform the Firmware Update.
3. Is there a Compact Flash memory card installed?
Yes- No further action is required
No- Restore the configuration that was saved in Step 1 (System -> Configuration
Management -> Upload and Restore all config and voice data).
This is necessary to restore the extension custom voice messages and the custom
Auto Attendant messages.
Attention: Always power down the Quadro before inserting/removing any Compact Flash card. The
largest recommended Compact Flash card is 8GB.
7.4 13BLimitations and restrictions
The memory used by "DSP Capture", "Call Capture" and "Network Capture" hidden pages is
limited to 3 MB. This will put a limitation on the duration of captured file
In case if voice mail recording codec is other than PCMU, the maximum length of VM sent by
email is limited to 3 minutes
The number of VMs in the mailbox for one extension is limited to 300
Use Session Timer in IP Line Settings is deselected by default