Epygi Technologies Hidden Pages for Quadro Advanced Configuration
Figure 8 Extension Management page for extension 11
To edit any of the advanced settings using the Extensions Management page, click on the link
associated with the corresponding extension or attendant.
3.5 fxocfg.cgi
The Fxo Configuration page allows configuring the FXO port settings to match the
characteristics of PSTN lines (see Figure 9).
Please Note: All settings found on this page are automatically adjusted to the regional settings
set in the System Configuration Wizard. It is strongly recommended to leave the settings with
their default values unless the characteristics of a specific PSTN line differ from those predefined
for the region.
The following settings are found on the Fxo Configuration page (see Figure 9):
Custom Fxo Disconnect Settings: Enables the manual configuration of disconnect-call
detection settings. Central offices (COs) typically use any or a mixture of the following three
methods to notify call disconnection:
1. Disconnect notification by sending busy/disconnect tones. The CO sends specific
tones to notify that the call party has hung up. To configure the Quadro to detect
disconnect tones and close the call upon detection, enable the Busy Detection checkbox
and specify the following settings:
o Frequency 1: Frequency of the disconnect tone used by CO. If the CO sends dual tone
signals, enter the high frequency of the tone into the Frequency 1 text field and the
low frequency into the Frequency 2 text field. In case of single tone signals, set the
Frequency 2 to 0.
o Duration: Tone duration in ms.
o Duration Disp: Amount of time (ms) that the tone signal may vary from its assigned
value. It should be chosen reasonably large taking into account the value of Duration.
By default 100 ms is recommended.
o Silence and Silence Disp: Silence duration and the amount (in ms) that it may vary
respectively.
o Pattern Count: Number of tone(s)-silence patterns the system should identify as a
disconnect notification. Leave the factory default value if the exact number is
unavailable.
PAGE 10 17-Feb-15